The most popular portables:
klik voor demo film
Fluke 62
-30°C till 500°C
Fluke 62
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -30°C till 500°C |
| Model | Fluke 62 |
| Spectral response | 8-14 µm |
| Emissivity | 0,95 |
| Distance to Spot (D:S) | 10:1 |
| Temperature measurement accuracy | ±1,5%, or ±1,5°C (±3°F) whichever is greater |
| Distance | Up to 2m (6ft) to infinity for spot > 20cm |
| Laser sighting system | Yes |
| Holster | Yes |
| Price (Euro) | 89 |
| Link | |
| Specifications subject to change without notice. | |
Fluke 62 MAX
-30°C till 500°C
Fluke 62 MAX
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -30°C till 500°C |
| Model | Fluke 62 MAX |
| Spectral response | 8-14 µm |
| Emissivity | adjustable |
| Distance to Spot (D:S) | 10:1 |
| Temperature measurement accuracy | ±1,5%, or ±1,5°C (±3°F) whichever is greater |
| Distance | Up to 2m (6ft) to infinity for spot > 20cm |
| Laser sighting system | Yes |
| Holster | Yes |
| Price (Euro) | 99 |
| Link | |
| Specifications subject to change without notice. | |
Fluke 62 MAX +
-30°C till 650°C
Fluke 62 MAX +
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -30°C till 650°C |
| Model | Fluke 62 MAX + |
| Spectral response | 8-14 µm |
| Emissivity | adjustable |
| Distance to Spot (D:S) | 12:1 |
| Temperature measurement accuracy | ±1,0%, or ±1,0°C (±2°F) whichever is greater |
| Distance | Up to 2m (6ft) to infinity for spot > 20cm |
| Laser sighting system | Yes |
| Holster | Yes |
| Price (Euro) | 119 |
| Link | |
| Specifications subject to change without notice. | |
Fluke FoodPro
Use FoodPro Series thermometers to quickly verify proper temperatures of food products at the point of delivery as recommended by your HACCP program.-30°C till 200°C
Fluke FoodPro
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -30°C till 200°C |
| Model | Fluke FoodPro |
| Spectral response | 8-14 µm |
| Emissivity | 0,97 |
| Distance to Spot (D:S) | 2,5:1 |
| Temperature measurement accuracy | -30 to 0°C: ±1°C +0.1 degree/degree 0 to 65°C: ±1°C above 65°C: 1.5% of reading |
| Distance | Up to 2m (6ft) to infinity for spot > 20cm |
| Laser sighting system | LED |
| Holster | Yes |
| Price (Euro) | 96 |
| Link | |
| Specifications subject to change without notice. | |
Fluke FoodPro Plus
Use FoodPro Series thermometers to quickly verify proper temperatures of food products at the point of delivery as recommended by your HACCP program.-35°C till 275°C
Fluke FoodPro Plus
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -35°C till 275°C |
| Model | Fluke FoodPro Plus |
| Spectral response | 8-14 µm |
| Emissivity | 0,97 |
| Distance to Spot (D:S) | 2,5:1 |
| Temperature measurement accuracy | -35 to 0°C: ±1°C +0.1 degree/degree 0 to 65°C: ±1°C above 65°C: 1.5% of reading (IR) |
| Distance | Up to 25 cm to infinity for spot > 10cm |
| Laser sighting system | LED |
| Holster | Yes |
| Price (Euro) | 175 |
| Link | |
| Specifications subject to change without notice. | |
Fluke 66 (obsolete!)
-32°C till 600°C
Fluke 66 (obsolete!)
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -32°C till 600°C |
| Model | Fluke 66 (obsolete!) |
| Spectral response | 8-14 µm |
| Emissivity | adjustable |
| Distance to Spot (D:S) | 30:1 |
| Temperature measurement accuracy | ±1% of reading or ±1 °C (±2 °F) whichever is greater |
| Distance | Up to 6m (24ft) to infinity for spot > 20cm |
| Laser sighting system | Yes |
| Holster | Optional |
| Price (Euro) | 436 |
| Link | |
| Specifications subject to change without notice. | |
Fluke 68 (obsolete!)
-32°C till 760°C
Fluke 68 (obsolete!)
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -32°C till 760°C |
| Model | Fluke 68 (obsolete!) |
| Spectral response | 8-14 µm |
| Emissivity | adjustable |
| Distance to Spot (D:S) | 50:1 |
| Temperature measurement accuracy | ±1% of reading or ±1 °C (±2 °F) whichever is greater |
| Distance | Up to 10m (40ft) to infinity for spot > 20cm |
| Laser sighting system | Yes |
| Holster | Optional |
| Price (Euro) | 562 |
| Link | |
| Specifications subject to change without notice. | |
Fluke 561
-40°C till 550°C
Fluke 561
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -40°C till 550°C |
| Model | Fluke 561 |
| Spectral response | 8-14 µm |
| Emissivity | 0,3; 0,7; 0,95 |
| Distance to Spot (D:S) | 10:1 |
| Temperature measurement accuracy | ±1% of reading or ±1 °C (±2 °F) whichever is greater |
| Distance | Up to 10m (40ft) to infinity for spot > 20cm |
| Laser sighting system | Yes |
| Holster | Optional |
| Price (Euro) | 168 |
| Link | |
| Specifications subject to change without notice. | |
Fluke 566
-40°C till 650°C
Fluke 566
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -40°C till 650°C |
| Model | Fluke 566 |
| Spectral response | 8-14 µm |
| Emissivity | adjustable |
| Distance to Spot (D:S) | 10:1 |
| Temperature measurement accuracy | ±1% of reading or ±1 °C (±2 °F) whichever is greater |
| Distance | Up to 10m (40ft) to infinity for spot > 20cm |
| Laser sighting system | Yes |
| Holster | Optional |
| Price (Euro) | 427 |
| Link | |
| Specifications subject to change without notice. | |
Fluke 568
-40°C till 800°C
Fluke 568
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -40°C till 800°C |
| Model | Fluke 568 |
| Spectral response | 8-14 µm |
| Emissivity | adjustable |
| Distance to Spot (D:S) | 10:1 |
| Temperature measurement accuracy | ±1% of reading or ±1 °C (±2 °F) whichever is greater |
| Distance | Up to 10m (40ft) to infinity for spot > 20cm |
| Laser sighting system | Yes |
| Holster | Optional |
| Price (Euro) | 562 |
| Link | |
| Specifications subject to change without notice. | |
Fluke 572
Special model available for -50ºC to 500ºC-30°C till 900°C
Fluke 572
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -30°C till 900°C |
| Model | Fluke 572 |
| Spectral response | 8-14 µm |
| Emissivity | adjustable |
| Distance to Spot (D:S) | 60:1 |
| Temperature measurement accuracy | ±0.75% of reading or ±1ºC (±2ºF) whichever is greater |
| Distance | Up to 10m (40ft) to infinity for spot > 20cm |
| Laser sighting system | 3-dot laser sighting (Meets IEC Class 2 & FDA Class II requirements) |
| Holster | Optional |
| Price (Euro) | 940 |
| Link | |
| Specifications subject to change without notice. | |
Fluke 574
Special model available for -50ºC to 500ºC, including datarecorder for 100 mesure points.-30°C till 900°C
Fluke 574
click here for a comparison with Raytek portables:
| Temperature Range (°C) | -30°C till 900°C |
| Model | Fluke 574 |
| Spectral response | 8-14 µm |
| Emissivity | adjustable |
| Distance to Spot (D:S) | 60:1 |
| Temperature measurement accuracy | ±0.75% of reading or ±1ºC (±2ºF) whichever is greater |
| Distance | Up to 10m (40ft) to infinity for spot > 20cm |
| Laser sighting system | 3-dot laser sighting (Meets IEC Class 2 & FDA Class II requirements) |
| Holster | Optional |
| Price (Euro) | 1401 |
| Link | |
| Specifications subject to change without notice. | |